供應(yīng)二手現(xiàn)貨Agilent/HP/37717C/通訊信號(hào)分析儀

 OmniBER 717 communications performance analyzer offers a one box, field portable multi-rate tester to 622Mb/s for installation, maintenance, and commissioning of today$$$s hybrid PDH/SDH/SONET and ATM transport networks and network equipment.

OmniBER 717 can be configured as a dual standard SONET/SDH analyzer for BER and jitter tests which makes it the ideal tool for testing network equipment in a manufacturing environment. The dual SONET/SDH capability along with comprehensive remote control of the instruments rich feature set means that production lines can be rapidly reconfigured to test either SONET or SDH. Training costs and program development times are reduced as there is only one easy-to-use interface to learn.


The Universal Instrument Driver (UID) software which is shipped as standard with OmniBER 717 greatly reduces test software development time. UID$$$s simplify programming since detailed knowledge of SCPI is not required - programming OmniBER can be easily done from a graphical programming environment such as VEE or LabVIEW.


Optical 1310nm and 1550nm interfaces at 51Mb/s ( STM-0/OC-1), 155Mb/s (STM-1/OC-3) and 622Mb/s (STM-4/OC-12) are supported, as well as electrical interfaces at all the commonly used ecom rates. PDH interfaces from 704kb/s to 140Mb/s (E4) and DSn interfaces at 1.5Mb/s (DS1) and 45Mb/s (DS3) are supported. The measurement capability is configured using a modular architecture, allowing flexible configurations and full upgradeability, thus protecting your investment in test equipment.


The instrument can be configured to include DSn, PDH, SONET, SDH, ATM and jitter. Alternatively it can be configured to have any one of these technologies with or without jitter generation and measurement.


Use OmniBER 717 to perform non-intrusive monitoring of live traffic or test network protection switching mechanisms, perform out-of-service BER measurements or fully test ATM physical and cell layers and B. ISDN protocol stack layers. Functionally test PDH/DSn/SDH/SONET multiplexors, regenerative repeaters, digital cross connects, etc., as well as ATM switches, routers and rate converters.


Stress network elements by performing frequency offset, auto-jitter tolerance, auto-jitter transfer and output jitter measurements to ITU-T recommendations. Important parametric tests such as protection switch times, frequency, delay and power measurement are also supported.


General

 


Accurate protection switching time measurement

Optical power measurement

Auto-setup and preset functions

Stored error and alarm results graphics (1 second resolution)

Print on demand, print all

Integral graphics 80-column printer with screen dump facility

External printing (GPIB, RS-232-C)

Alarms/errors indicators and trouble scan mode

Remote control (GPIB, RS-232-C, LAN)

Integral disc drive, VGA output.


SONET

 


Dual standard SONET/SDH

OC-12c, OC-12, OC-3c, OC-3, OC-1, STS-3c, STS-1, DS3, DS1 interfaces

Errror and alarm generation/detection

Graphical in-service SONET alarm and BIP scan

Overhead access, overhead sequences, overhead BER, DCC drop/insert

AU-3 and AU4 mapping rates for international gateway testing

DSn/PDH drop/insert (from/to SONET/SDH)

Thru-data mode (transparent, overhead, overwrite and tributary add/drop)

Frequency and optical power measurements

ITU-T G.826 and M.2100/M.2110 and M2120 analysis


SDH

 


STM-4o, STM-1o, STM-1e, STM-0,140 Mb/s, 34 Mb/s, 8 Mb/s, 2 Mb/s, 704 kb/s interfaces

SDH binary (NRZ) interfaces

Error and alarm generation/detection

Graphical in-service SDH alarm and BIP scan

Overhead access, overhead sequences, overhead BER, DCC drop/insert

140 Mb/s, DS3, 34 Mb/s, 2 Mb/s, DS1 and VC-4, VC-3, TU-3, TU-2, TU-12 bulk-filled payloads

Pointer sequence generation and pointer analysis

PDH drop/insert (from/to SDH signal)

Thru-data mode (transparent, overhead overwrite and AU/TU tributary add-drop)

SDH jitter generation/analysis to ITU-T G.825/G.958 and O.171.

Frequency and optical power measurement

Protection switch times and delay time measurement

ITU-T G.826 and M.2100/M.2110 and M.2120 analysis. 

 

儀器保證:

我們的大多數(shù)設(shè)備在裝運(yùn)之前均經(jīng)過(guò)嚴(yán)格的質(zhì)量檢測(cè)與校驗(yàn)。也可申請(qǐng)國(guó)家計(jì)量證書(shū)。

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。

溫馨提示:為規(guī)避購(gòu)買(mǎi)風(fēng)險(xiǎn),建議您在購(gòu)買(mǎi)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

撥打電話(huà)
在線(xiàn)留言
主站蜘蛛池模板: 池州市| 农安县| 石景山区| 郁南县| 娱乐| 宜兰市| 宝兴县| 五常市| 探索| 正蓝旗| 丰顺县| 中卫市| 孟津县| 自治县| 蒙自县| 耒阳市| 枞阳县| 化州市| 闽侯县| 泗水县| 尉氏县| 宁阳县| 桃园县| 奉贤区| 泰州市| 岗巴县| 大方县| 贵定县| 乐东| 铅山县| 宝鸡市| 绥化市| 繁峙县| 平凉市| 志丹县| 山东| 白河县| 广汉市| 古交市| 乐亭县| 澄江县|