久久无码人妻一区二区三区午夜_久久久久精品久久久久影院蜜桃_亚洲综合欧美色五月俺也去_交换娇妻呻吟声不停中文字幕

您好, 歡迎來到化工儀器網

| 注冊| 產品展廳| 收藏該商鋪

13224517959

products

目錄:上海希言科學儀器有限公司>>美國戴安Dionex>> 美國戴安 P/N: 079013Dionex Acclaim Carbonyl LC Column 液相色譜柱

Dionex Acclaim Carbonyl LC Column 液相色譜柱
  • Dionex Acclaim Carbonyl LC Column 液相色譜柱
  • Dionex Acclaim Carbonyl LC Column 液相色譜柱
參考價 面議
具體成交價以合同協議為準
參考價 面議
具體成交價以合同協議為準
  • 品牌 DIONEX/英國
  • 型號 美國戴安 P/N: 079013
  • 廠商性質 代理商
  • 所在地 上海
屬性

>

更新時間:2018-04-24 14:05:21瀏覽次數:810評價

聯系我們時請說明是化工儀器網上看到的信息,謝謝!

同類優質產品

更多產品
戴安公司生產的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術優勢和方法已廣泛地應用于各個領域,其*達80%。與離子色譜相關的文章有90%均出自戴安公司生產的離子色譜儀。

Acclaim Carbonyl LC Column 

High Resolution HPLC of Aldehyde and Ketone Contaminants

The Thermo Scientific Acclaim* Carbonyl C18 HPLC columns are designed specifically for superior resolution and high-throughput separation for DNPH derivatives of aldehydes and ketones regulated by the U.S. Environmental Protection Agency (EPA) in methods such as EPA 554, EPA 8315, EPA 1667, EPA TO-11, and by the California Environmental Protection Agency Air Resources Board in method CARB 1004.

  • High efficiency for UHPLC performance
  • Rugged columns with good lot-to-lot reproducibility
  • Proven robust methods

Carbonyl compounds, including low molecular weight aldehydes and ketones, cause environmental and health concerns. Because of their highly volatile and reactive nature, carbonyl compounds are often converted to the dinitrophenylhydrazine (DNPH) derivatives prior to analysis. The Acclaim Carbonyl C18 columns are high-performance reversed-phase columns specifically designed for high throughput and baseline separation of thirteen DNPH derivatives of aldehydes and ketones regulated by CARB Method 1004. In addition, the same chromatographic method can be applied directly to other regulatory methods such as EPA 554, EPA 8315, and EPA TO-11.

The columns are available in three particle sizes:  2.2, 3 and 5?m. Smaller particle sizes provide high peak efficiency for fast analysis. Small internal diameter (i.d.) columns (e.g., 2.1 and 3.0 mm) consume less solvents and produce less chemical waste. For high-throughput application, the 2.1 × 100 mm column format combined with high linear velocity should be considered. When high resolution power is desired, a longer column (2.1 × 150 mm) can be used at an optimal linear velocity to achieve even better resolution.

技術參數:


Acclaim Carbonyl C18 Column Specifications
Column chemistryProprietary alkyl group
Operating pressure limit (recommended)

800 bar for 2.1 x 150mm; 2.2?m

600 bar for 2.1 x 150mm; 3.0 ?m

600 bar for 2.1 x 100mm

700 bar for 3.0 x 100mm

600 bar for 3.0 x 150mm

800 bar for 3.0 x 250mm

Operating pH range (recommended)2.5–7.5
Operating flow rate range (recommended)0.4–1.4  mL/min for 3.0 mm i.d. formats
0.25–0.75  mL/min for 2.1 mm i.d. formats
Operating temperature (recommended)25 -35 °C

訂購信息:



Analytical Columns
Acclaim Carbonyl RSLC Analytical,2.2?m (2.1 x 100mm)077972
Acclaim Carbonyl RSLC Analytical,2.2?m (2.1 x 150mm)077973
Acclaim Carbonyl RSLC Analytical,2.2?m (3.0 x 100mm)077974
Acclaim Carbonyl C18 Column 3?m Analytical (2.1 x 150 mm)079011
Acclaim Carbonyl C18 Column 3?m Analytical (3.0 x 150 mm)079010
Acclaim Carbonyl C18 Column 3?m Analytical (3.0 x 250 mm079009
Acclaim Carbonyl C18 Column 5?m Analytical (4.6 x 150 mm)079008
Guard Columns
Acclaim Carbonyl C18 Column 5?m Guard (2.1 x 10 mm), 2/pk079012
Acclaim Carbonyl C18 Column 5?m Guard (3.0 x 10 mm) , 2/pk079013
Acclaim Carbonyl C18 Column 5?m Guard (4.6 x 10 mm), 2/pk079014


會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

您的留言已提交成功!我們將在第一時間回復您~
在線留言

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:
熱線電話 在線詢價
主站蜘蛛池模板: 长顺县| 陕西省| 祥云县| 乐清市| 高尔夫| 恩施市| 鹤峰县| 盖州市| 定边县| 克东县| 美姑县| 陈巴尔虎旗| 吉隆县| 包头市| 出国| 谢通门县| 北安市| 体育| 荔波县| 资源县| 炎陵县| 赤峰市| 永和县| 启东市| 华池县| 灵璧县| 邵武市| 绥芬河市| 屏边| 大悟县| 隆安县| 神农架林区| 理塘县| 上虞市| 高台县| 铁岭县| 秭归县| 南投县| 读书| 孝感市| 贡嘎县|