LONZA PYROGENT-5000 100 Test Kit
參考價 | 面議 |
- 型號
- 品牌
- 廠商性質 生產商
- 所在地 上海市
更新時間:2016-01-06 19:22:53瀏覽次數:1155
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
PYROGENT -5000產品適合用于實驗室處理大量樣品,可以定量的動態檢測革蘭氏陰性細菌內毒素。檢測在96孔板上進行,允許許多樣品同時檢測。The PYROGENT™–5000 assay是水樣,大量注射用藥物和醫療設備沖洗水內毒素檢測的理想選擇。檢測使用溫育板讀數器340nm讀數,檢測靈敏度在0.01 to 100.0 EU
產品英文名稱:PYROGENT™–5000 Kinetic Turbidimetric LAL Assays
產品中文名稱:PYROGENT™–5000動態濁度法內毒素檢測試劑盒
PYROGENT™–5000 Kinetic Turbidimetric LAL Assays產品介紹:
PYROGENT -5000產品適合用于實驗室處理大量樣品,可以定量的動態檢測革蘭氏陰性細菌內毒素。檢測在96孔板上進行,允許許多樣品同時檢測。The PYROGENT™–5000 assay是水樣,大量注射用藥物和醫療設備沖洗水內毒素檢測的理想選擇。檢測使用溫育板讀數器340nm讀數,檢測靈敏度在0.01 to 100.0 EU/ml。
檢測原理:樣品和LAL(鱟變形細胞裂物)反應物混合,革蘭氏陰性細菌內毒素催化LAL酶原反應,反應初速度決 定于內毒素濃度。激活的凝固酶原水解LAL凝固蛋白酶原特定化學鍵形成凝固蛋白。水解形成的凝固蛋白會立即自我凝集成膠狀物。LAL濁度法檢測可以測定濁 度增加值(光密度),濁度變化在凝膠形成之前出現。反應物變混濁所需時間(反應時間)與細菌內毒素含量成反比例。也就是說,如果有大量內毒素存在,則反應 迅速,很快就會出現混濁;如果有少量內毒素存在反應時間就會延長。未知樣品內毒素濃度可通過標準曲線計算出。
注意事項:
¡ 本品為體外診斷試劑,嚴禁用于人體內毒素檢測
¡ 本品用于藥品的G-細菌內毒素檢測時,應遵循USP藥典細菌內毒素檢測法的規定
¡ 如果說明書下載不了或者有其它產品信息問題可以咨詢
PYROGENT™–5000 Kinetic Turbidimetric LAL Assays英文介紹:
The PYROGENT™–5000 assay is perfect for laboratories needing to process large numbers of samples. This assay is performed in a 96-well plate allowing many samples to be processed at one time. It is ideal for water samples, large volume parenterals and water rinse from medical devices. The PYROGENT™–5000 assay is measured at the 340 nm wavelength and has a sensitivity range from 0.01 to 100.0 EU/ml. An incubating plate reader is required to run this assay.
PYROGENT -5000 is a quantitative, kinetic assay for the detection of Gram negative bacterial endotoxin. A sample is mixed with the reconstituted LAL reagent, placed in the photometer, and automatically monitored over time for the appearance of turbidity. The time required before the appearance of turbidity (Reaction Time) is inversely proportional to the amount of endotoxin present. That is, in the presence of a large amount of endotoxin the reaction occurs rapidly; in the presence of a smaller amount of endotoxin the reaction time is increased. The concentration of endotoxin in unknown samples can be calculated from a standard curve.
訂購信息:
N383(Cat.No.) 2瓶/盒(鱟試劑) 100Tests 5.2ml/瓶(需混合的LAL重配緩沖劑體積)
N384(Cat.No.) 2瓶/盒(鱟試劑) 200Tests 10.4ml/瓶(LAL重配緩沖劑體積)
N588(Cat.No.) 45瓶/盒(鱟試劑) 2250Tests 5.2ml/瓶(LAL重配緩沖劑體積)
N688(Cat.No.) 45瓶/盒(鱟試劑) 4500Tests 10.4ml/瓶(LAL重配緩沖劑體積)
- GE 淋巴細胞分離液面議
- BECKMAN貝克曼 38.5ml 超速離心管 現貨面議
- BECKMAN Vi-CELL Quad Pack試劑盒 現貨面議
- BECKMAN CytoFLEX Daily QC Fluorospheres面議
- D12108C 動脈粥樣硬化動物模型老鼠高脂飼料面議
- 第三代CHO宿主細胞蛋白ELISA檢測試劑盒面議
- Dojindo Cell Counting Kit-8 CCK-8細胞計數試劑盒面議
- GE 17-1440-03 Ficoll-Paque PLUS 淋巴細胞分離液 500mL面議
- R Diets 10 kcal% Fat(低脂飼料)Starter Box面議
- GEB 2.2mL 低吸附透明96方形孔深孔板,V型底面議
以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,化工儀器網對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。